Air circulation improvement

Improving Air Circulation in Older Commercial Buildings

Older buildings often have air that does not move where it should. Rooms are stuffy, upper floors run warm, and corners stay damp. The causes are usually changes made over the years, wear and a system designed for a different use. This guide gives a method for finding the cause and improving circulation.

Common reasons air does not move well

ReasonSignFix
Blocked or missing return pathsClosed rooms feel stuffy, doors whistle or are hard to closeAdd transfer grilles or ducts, undercut doors where permitted
Partitions added laterRooms with no supply or returnExtend ducts and add outlets, then re-balance
Leaky or damaged ductsRooms at the end of runs get little airSeal and repair, then measure
Fans and drives worn or wrongLow airflow overallRepair or replace, then adjust to design
Dampers seizedCannot adjust airflowFree or replace and mark positions
Stratification in tall spacesWarm air collects highDestratification fans or better supply diffusers
Little or no outdoor airStale air throughoutRestore outdoor air path and verify quantity

A method for improving circulation

  1. Walk the building and note stale, warm and damp areas.
  2. Check the equipment: fans, filters, coils and dampers.
  3. Measure airflow at outlets and total airflow at each fan, and compare with the original design if it exists.
  4. Check the return paths, especially to rooms that were partitioned.
  5. Repair what is broken, then balance.
  6. Consider added ventilation or energy recovery if outdoor air is far below what the use requires.
  7. Record the readings as the new baseline.

See what to check before retrofitting an older building and TAB for retrofit projects.

About ceiling fans and destratification

In tall spaces, slow-moving fans can push warm air back down in winter, reducing heating cost and improving comfort. In summer, air movement can improve comfort at the occupied level. They do not bring in outdoor air, so they work alongside ventilation, not in place of it.

Common mistakes

  • Adding fans before fixing airflow. They move stale air around.
  • Cutting holes in walls for returns without fire protection. Check with the building and fire codes.
  • Not re-balancing after changes. Airflow moves with every change.

Questions owners ask about older buildings

Can we improve circulation without replacing the system?

Often yes. Repairs, return paths and balancing deliver a lot before any new equipment is considered.

How do we know the original design airflow?

From original drawings and any earlier TAB report. If none exist, measure now, and size changes to current needs.

What is the first measurement?

Total airflow at each air handler and outdoor air. See what a balance involves.

To measure and improve circulation in an older building, call Ghazi Hussain at (908) 323-9780 for a quote.

Need Help?

Ghazi-Hussain-Air-Balance-Masters