Indoor air quality compliance

How Facility Managers Can Stay Compliant with Air Quality Regulations

Indoor air quality is covered by a mix of codes, standards and general duties, not one rule. For a facility manager, staying compliant is mostly a matter of knowing which apply to your building and keeping proof.

Where the requirements come from

  • Building and mechanical codes. They set ventilation and exhaust requirements, often by reference to ASHRAE Standard 62.1. Your local authority adopts a specific edition. See the commercial ventilation standards guide.
  • OSHA. There is no single OSHA standard for indoor air quality in most workplaces. OSHA publishes guidance, and specific contaminants are covered by their own rules. Employers also have a general duty to provide a workplace free from recognized hazards.
  • Local and state health departments. They may set rules for certain building types or conditions.
  • Industry standards and accreditation. Healthcare facilities follow ASHRAE/ASHE 170. See air quality rules in healthcare design.
  • Leases and certifications. Tenants and programs such as LEED may add requirements.

What to keep on file

  1. The design ventilation rates for each system.
  2. The latest TAB report, with measured outdoor air quantities.
  3. Filter schedule and change records.
  4. Maintenance logs for coils, drain pans and humidifiers.
  5. A log of IAQ complaints and what was done about each.
  6. Any IAQ test results.

A compliance calendar

WhenWhat
MonthlyReview complaints and filter pressure drops
Each seasonInspect drain pans, coils, humidifiers, economizers
AnnuallyVerify sensors, review ventilation rates against occupancy
After changesRe-measure outdoor air and airflow

Questions facility managers ask about compliance

What do auditors usually ask for?

Evidence of ventilation rates, maintenance records and test reports. A measured TAB report with outdoor air quantities answers the first and last.

What if the building changed use?

Recalculate the ventilation requirement for the new use and occupancy, then verify what the system delivers. A change from storage to office, for example, raises the requirement.

Which edition applies to us?

Ask the authority that issued your permit, and check your design documents. Do not assume the newest edition applies.

Gaps auditors and inspectors commonly find

  • No measured outdoor air quantity, only design drawings.
  • Outdoor air dampers closed down or inoperable.
  • Filter changes undocumented.
  • Drain pans with standing water or biological growth.
  • Use of a space changed with no review of ventilation.
  • Complaints logged but no record of action.

Who owns what

ResponsibilityUsually owned by
Building ventilation designDesign engineer
Verification that the system delivers itTAB contractor
Day-to-day maintenance and recordsFacility team or service contractor
Compliance review and sign-offFacility manager and owner
Code adoption and enforcementLocal authority

Write the table for your own building, naming the person in each row. Gaps usually sit between rows, where each party assumed another would handle it.

When a complaint turns into a claim

If an occupant reports a health concern, treat it seriously and document what you did. Check ventilation and moisture first, then bring in an indoor air quality professional if the cause is unclear. A dated record of your response is the most useful thing you can have later.

Related reading: How to Ensure Compliance with Air Quality Regulations in Design and How to Ensure Compliance with Indoor Air Quality Regulations in Schools.