Smart Home Air Quality

Smart Sensors and Controls for Air Quality in Buildings

Sensors can show what the air is doing, and controls can act on it. They help only if the data is accurate and someone uses it. This guide covers the sensors worth installing, where to place them and how to avoid the common traps.

Sensors and what they tell you

SensorWhat it showsNotes
Carbon dioxide (CO2)Ventilation per personGood for rooms with variable occupancy, and a rough indicator only
Temperature and humidityComfort and moisture riskCheck against a reference at startup
Fine particles (PM2.5)Particle levelsUseful for smoke events and filtration checks, and accuracy varies by sensor
VOCsGeneral chemical loadGives a trend, not a specific compound
Airflow and pressureHow the system is moving airMore accurate for control than inferred values

Placement

  • Place room sensors at breathing height, away from supply air, doors and windows.
  • Put CO2 sensors in the rooms with the most variable occupancy, such as meeting rooms and classrooms.
  • Place outdoor air quality sensors away from local sources, such as exhaust and vehicles.
  • Document each sensor’s location, so readings can be interpreted.

Accuracy decides value

Low-cost sensors can drift, and some are affected by temperature or humidity. Calibrate or check them against a reference at installation and on a schedule. Wrong readings can drive the wrong control action, such as ventilating too little or too much. A measured air balance gives you a true airflow baseline to compare with.

Putting sensors to work

  1. Trend first. Watch the data for a few weeks to learn what normal looks like.
  2. Set alerts for clear problems, such as CO2 staying high through a day.
  3. Link to controls carefully. Demand-controlled ventilation can reduce outdoor air when rooms are empty, but the minimum must still meet the standard.
  4. Review monthly. Someone should look at the data and act.
  5. Keep records. A log of changes explains later shifts in the data.

See what to require from smart HVAC and interoperability in smart HVAC.

Privacy and security

Room-level sensors can reveal patterns of occupancy. Tell occupants what you collect and why. Connected sensors also need network security, so involve IT and avoid default passwords.

Common mistakes

  • Buying many sensors with no plan. Data nobody reads has no value.
  • Trusting a sensor out of the box. Check it.
  • Cutting outdoor air on a CO2 signal alone. Other pollutants may be present.

Questions facility managers ask about air quality sensors

Which sensor should I start with?

CO2 and humidity in a few representative rooms. They are cheap and informative.

Can a smart system replace maintenance?

No. It points to problems, and people still have to fix them.

How do I know the data is right?

Compare with a calibrated reference and with measured airflow.

To give your sensors a verified airflow baseline, call Ghazi Hussain at (908) 323-9780 for a quote.

Need Help?

Ghazi-Hussain-Air-Balance-Masters