In a healthcare facility, filtration is a layer of infection control. Filters capture particles that carry pathogens, and they only work if they are the right grade, fitted well and changed with care. This guide covers the main points.
Filter banks and where they go
| Component | Role |
|---|---|
| Prefilters | Capture larger particles and protect finer filters |
| Final filters in the air handler | Provide the main filtration for supply air |
| HEPA filters | Capture very small particles, used where the design calls for them, such as protective environment rooms and some critical spaces |
| Terminal filters | Filters at the room supply, where specified |
ASHRAE/ASHE Standard 170 sets the filtration required for each space type. Check the edition adopted by your jurisdiction, and the facility’s design documents. For general filter selection, see our guide to air filtration.
Why pressure drop matters
Finer filters resist airflow more, and loaded filters resist more still. Rising pressure drop cuts airflow, which changes air changes per hour and pressure relationships between rooms. Install gauges across each bank, record readings and change filters at the limit set for the equipment. After any change, confirm airflow and pressure are still at design.
Installation and testing
- Seal the frames. Air takes the easy path around poorly fitted filters.
- HEPA filter installations are leak tested after installation, using a method the specification names.
- Record filter type, rating and location for each bank.
- Verify airflow and pressure relationships after a filter change.
Changing filters safely
Filter changes in healthcare air handlers can release dust and microorganisms. Follow the facility’s infection control procedures, including risk assessment, protective equipment and bagging of used filters. See the ICRA checklist for TAB teams.
Records worth keeping
A filter log for each air handler: date, type, gauge readings before and after, and the person. Keep the HEPA leak test reports. Accreditors and regulators may ask to see them, and they help trace a problem back to a change.
Common mistakes
- Upgrading to a finer filter without checking the fan. Airflow can fall below design.
- Skipping leak tests after installing HEPA filters. A leaking seal defeats the filter.
- Changing filters without controls. The change itself can spread contaminants.
Questions facilities teams ask about healthcare filtration
Can I use portable air cleaners instead?
They can supplement the central system in some rooms, but they do not replace the design ventilation and filtration. Check with your infection prevention team.
How often should I change filters?
At the pressure drop limit for the equipment and the facility’s schedule, and not later.
How do I know airflow is still right?
Measure it after changes, and have rooms tested for pressure relationships. See air balancing in healthcare.
Related reading: Air Cleaners in Commercial Buildings: When They Help.
To verify airflow and pressure after filter changes, call Ghazi Hussain at (908) 323-9780 for a quote.
Related Posts
- How to Troubleshoot Common HVAC Problems in Large Buildings
- The Role of HVAC Systems in Reducing Infection Risks in Hospitals
- How to Ensure Compliance with Indoor Air Quality Regulations in Schools
- The Economic Benefits of Energy-Efficient HVAC Systems for Contractors
- The Importance of Air Balancing in Healthcare Environments
- The Economic Benefits of Sustainable HVAC System Design
- Understanding the Basics of Test, Adjust, and Balance (TAB) Services
- How to Reduce Energy Costs with Routine HVAC Inspections