HVAC maintenance tips

Top 10 HVAC Maintenance Tips for Facility Managers

A short list of tasks done on time prevents most HVAC breakdowns. These ten cover the equipment that fails most often in commercial buildings. Frequencies are typical, so follow the manufacturer’s schedule where it differs.

The ten tasks

  1. Change or check filters. Monthly to quarterly, or when the pressure drop reaches the limit on the gauge. Record the date and the reading.
  2. Clean coils. Annually, more often in dusty or coastal sites. Dirty coils cut capacity and raise energy use.
  3. Clear condensate drains. Quarterly in cooling season. A blocked drain is a leading cause of water damage.
  4. Inspect belts and sheaves. Quarterly. Look for wear and check tension and alignment.
  5. Lubricate bearings and check motors. Per the manufacturer. Record motor amps and compare them to the nameplate.
  6. Test the economizer. Twice a year. Drive the damper open and closed and confirm it moves. See how to diagnose economizers.
  7. Check refrigerant circuits. Annually, by a licensed technician.
  8. Verify thermostats and sensors. Annually. Compare each reading to a reference thermometer.
  9. Inspect ducts and dampers. Annually. Look for leaks, loose connections and dampers that have moved from their marked position.
  10. Re-verify airflow. After major changes, and every few years. Regular testing and balancing catches drift that no visual check will.

What to write down

For every visit, record the equipment ID, the date, the task, the person, any readings, parts used and anything unusual. Here is how to document maintenance so the records hold up.

Start with filters, drains and the economizer

If you have none of this in place, start with filters, drains and the economizer. They are cheap, they fail often, and the damage from missing them is expensive. Then build the rest into a schedule. Why preventative maintenance pays explains how to set it up.

Common mistakes

  • Changing filters on the calendar only. A filter in a dusty building may load up weeks early. Read the pressure gauge.
  • Cleaning coils with the wrong method. Pressure that is too high bends the fins. Use the method the manufacturer allows.
  • Skipping the drain pans. Standing water is a mold risk and an overflow risk.
  • Writing “OK” in the log. Record a number. A number can be compared next time.
  • Treating a comfort complaint as a one-off. Repeated complaints from one area point to an airflow or control problem.

What to hand a new technician

When someone new takes over the building, give them four things: the equipment list with locations, the maintenance schedule, the last TAB report with design airflow for each system, and the log of past work. With those, a new person can be useful in the first week instead of the first quarter.

Questions facility managers ask about HVAC maintenance

How often should filters be changed?

It depends on the filter, the equipment and how dusty the building is. Use the pressure gauge across the filter bank and change the filters when the pressure drop reaches the limit the manufacturer gives. Do not wait for a calendar date if the gauge says it is time, and do not change filters that are still clean just because the date arrived.

Which tasks need a licensed technician?

Work on refrigerant circuits does. In the United States, handling refrigerants requires certification under EPA rules. Electrical and gas work may also need licensed trades, depending on your state.

I inherited a building with no records. Where do I start?

Walk the equipment and make a list. Check filters, drains and economizers first. Then get a measured airflow baseline, so every later reading has something to compare with.

Related reading: The Link Between Proper HVAC Installation and Building Longevity.

For a baseline of how your system performs today, call Ghazi Hussain at (908) 323-9780.

Need Help?