Building Automation Trends

Trends in Building Automation Systems for General Contractors

Building automation has moved from a standalone control panel to a networked system that sits next to the IT department. For a general contractor, that changes scheduling, coordination and closeout. This guide covers the trends and what to do about each.

Trends and what they mean for the GC

TrendWhat it means on the project
Open protocols such as BACnet and ModbusEquipment from different makers can share one system, so specify and verify compatibility
Controls on the building networkIT must be at the table early for addresses, security and access
CybersecurityPasswords, patching and network separation become part of closeout
Wireless sensorsFaster installation, but battery and signal checks need to be documented
Analytics and fault detectionSoftware reads the trend data, so accurate sensors matter
Integration of systemsLighting, HVAC and access can share data, which raises coordination work

For the standards behind interoperability, see interoperability in smart HVAC.

What to put in the schedule

  1. A network and IP address plan agreed with the owner’s IT team.
  2. Controls programming ahead of testing and balancing.
  3. Functional testing of each sequence by the controls contractor and commissioning agent.
  4. Owner training on the interface and alarms.
  5. Handover of passwords, licenses and documentation.

The owner will ask about these

  • Who owns the data and the trend logs?
  • What happens if the controls vendor leaves?
  • How are default passwords changed and recorded?
  • Who updates the software?

How testing and balancing connects

Automated systems act on sensor readings, and they assume the airflow they were designed for. A measured balance gives the controls a verified baseline, and the balancer often needs the controls contractor to change settings during the work. Plan for the two to work together. See what to require from smart HVAC.

Common mistakes

  • Bringing IT in at the end. Network issues delay startup.
  • Leaving default passwords. A common and avoidable security hole.
  • Skipping sensor verification. Wrong readings drive wrong decisions.

Questions general contractors ask about building automation

Whose job is the controls network?

Usually shared between the controls contractor and the owner’s IT team. Define it in writing at kickoff.

Do I need a cybersecurity plan?

The owner may require one. At minimum, record who has access, change defaults and document the network layout.

When should controls be ready?

Before testing and balancing starts, so airflow and controls can be tested together.

A one-page closeout for controls

  • List of every controller with its address and location.
  • Sequences of operation as installed.
  • Network diagram, with port and security settings recorded.
  • Passwords and licenses, handed over to the owner in the agreed way.
  • Trend setup and the points the owner should watch.
  • Training record with dates and attendees.

An owner with this list can maintain the system, change vendors if needed and recover when something fails. An owner without it is dependent on whoever installed it.