Air balancing benefits

Understanding the Impact of Air Balancing on Building Performance

A building performs well when the air goes where the design says it should. Air balancing is the work that makes that so, and the effects show up in comfort, energy, ventilation and the number of complaints. This guide covers what changes and how to see it.

What air balancing changes

AreaBefore balancingAfter balancing
ComfortSome rooms too hot or cold, hot and cold spotsRooms on the same system settle to similar conditions
EnergyFans may move more air than needed, and rooms may be overcooled to compensate for starved onesFans run at design airflow and zones stop fighting
VentilationOutdoor air unknown or off designOutdoor air measured and set to design
NoiseHigh-velocity outlets and rattling dampersAirflow at design reduces velocity and noise
ComplianceNo evidence of performanceA report with measured values
MaintenanceNo baseline to compare withA baseline for fan, filter and pressure readings

How the effects show up

  • In complaints. The number and the pattern change. Complaints from one wing often stop completely.
  • In energy data. Fan power and reheat use fall when fans stop overfeeding.
  • In measured numbers. Airflow at each outlet moves toward the design and stays within tolerance.
  • In inspection. The report answers the questions a reviewer asks.

See what a balance involves and how airflow affects energy savings.

When to rebalance

  1. After a renovation, a change in the way rooms are used or a major equipment change.
  2. When complaints persist after the obvious fixes.
  3. When energy use rises with no clear cause.
  4. On a periodic cycle, so the baseline stays current.

A before-and-after example

Suppose a three-floor office has complaints from the third floor, which is warm in the afternoon. A balance finds the supply fan running 15 percent over design, the first and second floors receiving 120 percent of design airflow, and the third floor at 75 percent. The branch dampers are readjusted so every floor is near design and the fan is slowed to the design airflow. The third floor stops getting complaints, and the fan power falls. The numbers here are illustrative, but the mix of an over-driven fan and a starved zone is common.

Common mistakes

  • Expecting balancing to fix a load problem. If the room has more heat than the design assumed, airflow alone cannot fix it.
  • Balancing before the system is ready. Filters, dampers and controls have to work.
  • Not saving the report. It is the baseline for every later check.

Questions owners ask about air balancing

Will it lower our energy bill?

Often, where fans have been moving more air than the design needs, but it depends on your system. Measure first and compare bills afterward.

Does it need to be redone?

After major changes and on a regular cycle, since systems drift. See the economics of regular testing and balancing.

How long does it take?

A single rooftop unit with 10 to 15 registers typically takes about half a day, and larger projects can take 1 to 3 days.

To find out what balancing would change in your building, call Ghazi Hussain at (908) 323-9780 for a quote.

Need Help?

Ghazi-Hussain-Air-Balance-Masters